Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
PLoS One ; 17(9): e0269011, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36121796

RESUMO

Population surveillance in COVID-19 Pandemic is crucial to follow up the pace of disease and its related immunological status. Here we present a cross-sectional study done in Maricá, a seaside town close to the city of Rio de Janeiro, Brazil. Three rounds of study sampling, enrolling a total of 1134 subjects, were performed during May to August 2021. Here we show that the number of individuals carrying detectable IgG antibodies and the neutralizing antibody (NAb) levels were greater in vaccinated groups compared to unvaccinated ones, highlighting the importance of vaccination to attain noticeable levels of populational immunity against SARS-CoV-2. Moreover, we found a decreased incidence of COVID-19 throughout the study, clearly correlated with the level of vaccinated individuals as well as the proportion of individuals with detectable levels of IgG anti-SARS-CoV-2 and NAb. The observed drop occurred even during the introduction of the Delta variant in Maricá, what suggests that the vaccination slowed down the widespread transmission of this variant. Overall, our data clearly support the use of vaccines to drop the incidence associated to SARS-CoV-2.


Assuntos
COVID-19 , Cobertura Vacinal , Anticorpos Neutralizantes , Anticorpos Antivirais , Brasil/epidemiologia , COVID-19/epidemiologia , COVID-19/prevenção & controle , Estudos Transversais , Humanos , Imunoglobulina G , Incidência , Pandemias , SARS-CoV-2
2.
EBioMedicine ; 75: 103774, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34959134

RESUMO

BACKGROUND: Antigen-detecting rapid diagnostic tests (Ag-RDTs) for SARS-CoV-2 are important diagnostic tools. We assessed clinical performance and ease-of-use of seven Ag-RDTs in a prospective, manufacturer-independent, multi-centre cross-sectional diagnostic accuracy study to inform global decision makers. METHODS: Unvaccinated participants suspected of a first SARS-CoV-2 infection were recruited at six sites (Germany, Brazil). Ag-RDTs were evaluated sequentially, with collection of paired swabs for routine reverse transcription polymerase chain reaction (RT-PCR) testing and Ag-RDT testing. Performance was compared to RT-PCR overall and in sub-group analyses (viral load, symptoms, symptoms duration). To understandusability a System Usability Scale (SUS) questionnaire and ease-of-use (EoU) assessment were performed. FINDINGS: 7471 participants were included in the analysis. Sensitivities across Ag-RDTs ranged from 70·4%-90·1%, specificities were above 97·2% for all Ag-RDTs but one (93·1%).Ag-RDTs, Mologic, Bionote, Standard Q, showed diagnostic accuracy in line with WHO targets (> 80% sensitivity, > 97% specificity). All tests showed high sensitivity in the first three days after symptom onset (≥87·1%) and in individuals with viral loads≥ 6 log10SARS-CoV2 RNA copies/mL (≥ 88·7%). Usability varied, with Rapigen, Bionote and Standard Q reaching very good scores; 90, 88 and 84/100, respectively. INTERPRETATION: Variability in test performance is partially explained by variable viral loads in population evaluated over the course of the pandemic. All Ag-RDTs reach high sensitivity early in the disease and in individuals with high viral loads, supporting their role in identifying transmission relevant infections. For easy-to-use tests, performance shown will likely be maintained in routine implementation. FUNDING: Ministry of Science, Research and Arts, State of Baden-Wuerttemberg, Germany, internal funds from Heidelberg University Hospital, University Hospital Charité - Universitätsmedizin Berlin, UK Department of International Development, WHO, Unitaid.


Assuntos
Antígenos Virais/imunologia , Teste Sorológico para COVID-19 , COVID-19 , Sistemas Automatizados de Assistência Junto ao Leito , SARS-CoV-2/imunologia , Adulto , COVID-19/diagnóstico , COVID-19/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
3.
Mem Inst Oswaldo Cruz ; 116: e210085, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34406222

RESUMO

BACKGROUND: The high demand for adequate material for the gold standard reverse transcription real-time polymerase chain reaction (RT-qPCR)-based diagnosis imposed by the Coronavirus disease 2019 (COVID-19) pandemic, combined with the inherent contamination risks for healthcare workers during nasopharyngeal swab (NP) sample collection and the discomfort it causes patients, brought the need to identify alternative specimens suitable for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). OBJECTIVES: The aim of this work was to compare saliva and gingival fluid swabs to NP swabs as specimens for RT-qPCR-based SARS-CoV-2 diagnosis. METHODS: We compared gingival fluid swabs (n = 158) and saliva (n = 207) to the rayon-tipped NP swabs obtained from mild-symptomatic and asymptomatic subjects as specimens for RT-qPCR for SARS-CoV-2 detection. FINDINGS: When compared to NP swabs, gingival fluid swabs had a concordance rate of 15.4% among positive samples, zero among inconclusive, and 100% among negative ones. For saliva samples, the concordance rate was 67.6% among positive samples, 42.9% among inconclusive, and 96.8% among negative ones. However, the concordance rate between saliva and NP swabs was higher (96.9%) within samples with lower cycle threshold (Ct) values (Ct > 10 ≤ 25). MAIN CONCLUSIONS: Our data suggests that whereas gingival fluid swabs are not substitutes for NP swabs, saliva might be considered whenever NP swabs are not available or recommended.


Assuntos
Teste para COVID-19 , COVID-19 , Humanos , Nasofaringe , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2 , Saliva , Manejo de Espécimes
5.
Mem. Inst. Oswaldo Cruz ; 116: e210085, 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1287339

RESUMO

BACKGROUND The high demand for adequate material for the gold standard reverse transcription real-time polymerase chain reaction (RT-qPCR)-based diagnosis imposed by the Coronavirus disease 2019 (COVID-19) pandemic, combined with the inherent contamination risks for healthcare workers during nasopharyngeal swab (NP) sample collection and the discomfort it causes patients, brought the need to identify alternative specimens suitable for the diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). OBJECTIVES The aim of this work was to compare saliva and gingival fluid swabs to NP swabs as specimens for RT-qPCR-based SARS-CoV-2 diagnosis. METHODS We compared gingival fluid swabs (n = 158) and saliva (n = 207) to the rayon-tipped NP swabs obtained from mild-symptomatic and asymptomatic subjects as specimens for RT-qPCR for SARS-CoV-2 detection. FINDINGS When compared to NP swabs, gingival fluid swabs had a concordance rate of 15.4% among positive samples, zero among inconclusive, and 100% among negative ones. For saliva samples, the concordance rate was 67.6% among positive samples, 42.9% among inconclusive, and 96.8% among negative ones. However, the concordance rate between saliva and NP swabs was higher (96.9%) within samples with lower cycle threshold (Ct) values (Ct > 10 ≤ 25). MAIN CONCLUSIONS Our data suggests that whereas gingival fluid swabs are not substitutes for NP swabs, saliva might be considered whenever NP swabs are not available or recommended.


Assuntos
Humanos , Teste para COVID-19 , COVID-19 , Saliva , Manejo de Espécimes , Nasofaringe , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2
6.
J Toxicol Environ Health B Crit Rev ; 17(7-8): 369-410, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25495790

RESUMO

This is a cross-sectional review of biomarkers used in air pollution research from January 2009 through December 2012. After an initial keyword search in PubMed retrieving 426 articles, a comprehensive abstract review identified 54 articles of experimental design that used biomarkers of exposure or effect in human studies in the area of air pollution research during this specified time period. A thorough bibliographic search of the included articles retrieved an additional 65 articles meeting the inclusion criteria. This review presents these 119 studies and the 234 biomarkers employed in these air pollution research investigations. Data presented are 70 biomarkers of exposure with 54% relating to polycyclic aromatic hydrocarbons, 36% volatile organic carbons, and 10% classified as other. Of the 164 biomarkers of effect, 91 and 130 were used in investigating effects of short-term and chronic exposure, respectively. Results of biomarkers used in short-term exposure describe different lag times and pollutant components such as primary and secondary pollutants, and particle number associated with corresponding physiological mechanisms including airway inflammation, neuroinflammation, ocular, metabolic, early endothelial dysfunction, coagulation, atherosclerosis, autonomic nervous system, oxidative stress, and DNA damage. The review presents three different exposure scenarios of chronic, occupational, and extreme exposure scenarios (indoor cooking) with associated biomarker findings presented in three broad categories of (1) immune profile, (2) oxidative stress, and (3) DNA damage. This review offers a representation of the scope of data being explored by air pollution researchers through the use of biomarkers and has deliberately been restricted to this particular subject rather than an extensive or in-depth review. This article provides a contextualization of air pollution studies conducted with biomarkers in human subjects in given areas while also integrating this complex body of information to offer a useful review for investigators in this field of study.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar/análise , Biomarcadores/análise , Exposição Ambiental/análise , Poluentes Atmosféricos/efeitos adversos , Poluentes Atmosféricos/imunologia , Poluição do Ar/efeitos adversos , Dano ao DNA/imunologia , Exposição Ambiental/efeitos adversos , Monitoramento Ambiental , Humanos , Estresse Oxidativo/imunologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...